Public/Stop-GreenroomSession.ps1
|
# SPDX-License-Identifier: AGPL-3.0-or-later # Copyright (C) 2026 Tyler Vigario <# .SYNOPSIS Stop an instance's session, supervisor and launcher, and leave them stopped. .DESCRIPTION The gap this fills: every existing way to get a session to stop also brings it back. Restart-GreenroomSession stops it and starts the task again. Hide-GreenroomSession only moves the window -- the process keeps running and keeps its handles. Uninstall stops it by removing the instance, which is a different operation entirely. So the documented answer to "take this one down for a minute" was to stop the watchdog by hand and remember not to start anything, which is the procedure the module exists to replace. The case that makes it necessary is an upgrade of the Claude Code CLI -- and whether it does depends on how the CLI was installed. Both halves below are measured. MEASURED, on a probe process holding its own image, which is the Windows rule the rest of this follows from: overwrite in place / open for write / truncate FAIL, "being used by another process" delete FAIL, "Access to the path ... is denied" RENAME SUCCEEDS create a new file at the freed path SUCCEEDS delete the renamed original, still running FAIL -- succeeds once it exits So a running executable cannot be overwritten or deleted, but it CAN be renamed out of the way. One rule, and two installers that pick different sides of it. WinGet REMOVES. Every session runs through one WinGet\Links\claude.exe symlink into a single package file, and MEASURED: with a session running, `winget upgrade --id Anthropic.ClaudeCode` fails with 0x8a150003 and `remove: Access is denied` against that package file -- the delete row above. Hiding the window does not release the handle and restarting only re-takes it, so on a WinGet install this command is the workaround. The package is still published: `winget show --id Anthropic.ClaudeCode` resolves. The NATIVE updater RENAMES, so it needs no downtime at all. MEASURED 2026-11-09 with five sessions up: ~\.local\bin\claude.exe was renamed to claude.exe.old.1794251994594.15092 at 11:19:54 -- an epoch-ms stamp and the pid of a session holding it -- and the new 346,487,456-byte build was written at the freed path, with .last-update-result.json recording {"outcome":"success","path":"native"}. Sessions that started before the rename keep executing the renamed bytes; the orphan is 329 MB and CANNOT be deleted while any of them maps it. Two things follow that are easy to get backwards. `claude --version` starts a NEW process from the path, so it reports what is on DISK, not what a running session is executing. And on a native install, reaching for this command to make an upgrade safe buys nothing. What the command is for on every install is the gap in the first paragraph -- taking an instance down deliberately and having it STAY down. Nothing else does that. Order matters, and it is the same order Restart uses for the same reason. The watchdog goes first: it polls once a second and restarts a dead session, so killing the session first means racing a supervisor that is specifically designed to undo you. The task is stopped before any of it, so its trigger cannot start a replacement watchdog part-way through. That does NOT disable the task -- a stopped instance comes back at the next logon, or when Start-GreenroomSession is run, which is the intended behaviour for a supervised thing. Uninstall-GreenroomInstance is how you make it stay away. Everything is driven from the instance NAME, its scheduled task and config.json, never from session discovery. Discovery reads CommandLine, which is NULL across integrity levels, so a discovery-driven stop would be unusable from an unelevated shell against an elevated instance. REFUSES to stop the instance the calling shell is running inside. Killing an ancestor of this process mid-run means the settle check never executes, so the command cannot report the one thing it promises -- that the instance stayed down. Reaching for it from inside the session is the natural mistake, which is what makes the guard worth having. .PARAMETER Name The instance to stop. Wildcards match every registered instance, so `Stop-GreenroomSession *` acts on all of them. If omitted and exactly one instance is registered, that one is used. Accepts pipeline input, including Greenroom.Instance objects. .PARAMETER NoElevate Do not escalate when the instance runs elevated. Fails instead. Without it, an elevated instance is handed to an elevated copy through UAC -- ONE prompt for every elevated instance a pattern or pipeline matched, raised after the others have been stopped. .PARAMETER SettleSeconds How long to watch for the session coming back before reporting. Default 5. A surviving watchdog restarts a session within about a second, so this is long enough to catch one; 0 skips the check. .OUTPUTS Greenroom.StopResult -- what was actually stopped, as data rather than prose. .EXAMPLE Stop-GreenroomSession laptop-admin .EXAMPLE Stop-GreenroomSession laptop-admin -WhatIf Shows what would be stopped without touching anything. .EXAMPLE $running = (Get-GreenroomInstance).Instance $running | Stop-GreenroomSession # ...whatever actually needs every session down... $running | Start-GreenroomSession Taking every instance down and bringing back exactly what was up. Capture the names FIRST: Get-GreenroomInstance lists running sessions only, so once they are stopped it returns nothing, and capturing is also what avoids starting an instance that was down on purpose. Note that a Claude Code session you are typing in holds the same binary, so this frees it only if the shell running these commands is not itself inside one. The middle line is a placeholder because the right command depends on the install. `winget upgrade --id Anthropic.ClaudeCode` belongs there on a WinGet install, where the package file is locked by every running session. On a native install nothing belongs there, because the updater renames rather than removes and needs no downtime. See the DESCRIPTION. Either way the capture-first lesson is the point of the example, not the command in the middle. #> function Stop-GreenroomSession { [CmdletBinding(SupportsShouldProcess)] [OutputType('Greenroom.StopResult')] param( [Parameter(Position = 0, ValueFromPipeline, ValueFromPipelineByPropertyName)] [Alias('Instance')] [SupportsWildcards()] [string]$Name, [switch]$NoElevate, [ValidateRange(0, 60)] [int]$SettleSeconds = 5 ) begin { # Stopped instances are collected and settled together in `end`, once. Settling # inside the loop slept a full SettleSeconds after EACH instance, so `Stop *` over # six instances blocked for thirty seconds of pure sleep to learn what one pass # learns in five. $stopped = [System.Collections.Generic.List[object]]::new() # Elevated instances this shell cannot act on, escalated together in `end` so that # one UAC prompt covers all of them -- whether they came from one pattern or were # piped in one at a time. $deferred = [System.Collections.Generic.List[string]]::new() } process { # ONE INVOCATION, looping, as Start-GreenroomSession does. NOT a fan-out that # re-invokes the command once per matched instance: that shape is wrong in three # ways. -Confirm's "Yes to All" and "No to All" reset for every nested call, since # each has its own ShouldProcess state; a THROW in one nested call -- a declined # UAC prompt -- unwinds through the loop and abandons every instance after it; and # each nested call resolves its name all over again. foreach ($n in @(Resolve-InstanceName -Name $Name -Cmdlet $PSCmdlet)) { if (Test-SelfIsInstance -Name $n) { Write-CommandError -Cmdlet $PSCmdlet -ErrorId 'SessionIsSelf' -Category InvalidOperation -TargetObject $n -Message ( "'$n' is the session this shell is running inside. Stopping it from here would kill " + 'this process part-way through, so the settle check would never run and this could not ' + 'report whether it stayed down. Run it from a shell outside the session.') continue } # Gated before escalation, for the same reason Restart-GreenroomSession gates # there: a new elevated process starts with its own $WhatIfPreference and # $ConfirmPreference, so -WhatIf must stop here rather than be re-decided against # defaults over there, and -Confirm must prompt in the shell the operator typed in. if (-not $PSCmdlet.ShouldProcess($n, 'Stop-GreenroomSession')) { continue } if (-not (Assert-CanActOnInstance -Name $n -Command 'Stop-GreenroomSession' -NoElevate:$NoElevate -Defer $deferred -Cmdlet $PSCmdlet)) { continue } # Before the kills, so the trigger cannot launch a replacement watchdog while # they run. This only ends a task currently executing; it does not disable it. Stop-ScheduledTask -TaskName "greenroom-$n" -ErrorAction SilentlyContinue $shells = 'pwsh.exe', 'powershell.exe' $watchdog = Stop-VerifiedProcess -ProcessName $shells -Pattern (Get-InstanceScriptPattern -Script 'greenroom-watchdog.ps1' -Name $n) -Label 'watchdog' $session = Stop-VerifiedProcess -ProcessName 'claude.exe' -SessionOf $n -Label 'session' $launcher = Stop-VerifiedProcess -ProcessName $shells -Pattern (Get-InstanceScriptPattern -Script 'greenroom-launch.ps1' -Name $n) -Label 'launcher' if (($watchdog + $session + $launcher) -eq 0) { Write-Verbose "nothing was running for '$n'" } $stopped.Add([PSCustomObject]@{ Instance = $n; Watchdog = $watchdog; Session = $session; Launcher = $launcher }) } } end { # The elevated copy stops and settles its own instances, and its results do not # cross back -- only whether it succeeded does -- so they are reported here as an # error or not at all, as they were when each was escalated on its own. if ($deferred.Count) { Invoke-DeferredElevation -Command 'Stop-GreenroomSession' -Name $deferred -Cmdlet $PSCmdlet } # Confirm by observation, not by the kills returning. "Stopped" is only meaningful # if it is still stopped a moment later: a watchdog that was missed -- one belonging # to a stale asset version, say, whose command line does not match the pattern -- # puts the session straight back, and the counts would still look like success. # # Counted iterations rather than a wall-clock deadline. A deadline loop with the # sleep inside it degenerates into a busy-wait the moment the sleep does not # actually sleep -- which is exactly what happens under test. $cameBack = @{} if ($SettleSeconds -gt 0 -and $stopped.Count -gt 0) { for ($i = 0; $i -lt $SettleSeconds * 2; $i++) { Start-Sleep -Milliseconds 500 foreach ($s in $stopped) { if ($cameBack.ContainsKey($s.Instance)) { continue } $back = @(Get-GreenroomInstance -Name $s.Instance -WarningAction SilentlyContinue -ErrorAction SilentlyContinue) if ($back.Count -gt 0 -and -not $back[0].Opaque) { $cameBack[$s.Instance] = $true Write-Warning ("'$($s.Instance)' came back up while settling -- something is still supervising it. " + "Check for a watchdog from a different module version: Get-CimInstance Win32_Process " + "-Filter `"Name='pwsh.exe'`" | Where-Object CommandLine -match 'greenroom-watchdog'") } } if ($cameBack.Count -eq $stopped.Count) { break } } } foreach ($s in $stopped) { $stayedDown = -not $cameBack.ContainsKey($s.Instance) # An unelevated shell cannot read an elevated session's command line, so absence # is not evidence here. Saying so beats reporting a confirmation never made. $confirmed = $stayedDown if ((Test-InstanceElevated -Name $s.Instance) -and -not (Test-SelfElevated)) { $confirmed = $false Write-Warning ("cannot confirm '$($s.Instance)' stopped from an unelevated shell: an elevated " + 'session is unreadable here. Re-check with Get-GreenroomInstance from an elevated shell.') } # Returned rather than printed, matching Uninstall-GreenroomInstance: the facts # about what stopped are the ones an operator needs, and as data they can be # asserted on instead of read. [PSCustomObject]@{ PSTypeName = 'Greenroom.StopResult' Instance = $s.Instance WatchdogStopped = $s.Watchdog SessionStopped = $s.Session LauncherStopped = $s.Launcher StayedDown = $stayedDown Confirmed = $confirmed } } } } |